Ex-Floodlights of the series FMV LED / NSSFMV

Ex-Floodlight F2C LED
Donat Czapski

Donat Czapski – I am at your disposal

+48 695 244 220

info@grupa-wolff.com

Design
Delivery
Installation
Service

We know the requirements of insurers

From ATEX AUDIT to protection implementation

We provide 24/7 service

Ex-Floodlights of the series FMV LED / NSSFMV

(Zone 2, 22)

The new series of energy-saving FMV floodlights in LED technology are ideal for all ge­neral lighting applications in explosive gas atmospheres Zone 2 and in explosive dust atmospheres Zone 21 and 22. The floodlights with a light output from 3189 lm up to 15181 lm can be used to replace comparable conventional light sources with an equivalent power of 50 W up to 400 W. The new types NFMV 25L and 50L can even replace highest luminous flux power up to 600 W of conventional HP lamps. High efficient power LED modules with more than 112 lumen per watt enables up to 70 % energy cost reduction compared to HID fixtures.

LED technology for harsh environments

Due to the particularly solid construction of the housing and the vibration resistance of the LED module, the FMV LED floodlight is resistant to impact, shock and vibration. As a result, it represents the ideal lighting concept for use in areas with difficult environmental conditions. Thanks to the non-sensitive LED technology, even extreme temperatures from -40 °C up to +55 °C are not a problem. The robust, powder coated light metal housing in the degree of protection IP 66 and an impact-resistant lens meet the highest corrosion protection and mechanical resistance requirements.The advantages of the integrated, advanced LED technology with a high luminous flux and, at the same time, an extremely low energy consumption are a long service life and a high level of efficiency.

NFMV floodlights for high-pressure discharge lamps

The NFMV floodlights with high-gloss internal reflectors for high-pressure discharge lamps from 150 W up to 400 W are suited for operation in hazardous areas in Zone 2 and Zone 21 and ambient temperatures of -25 °C to +50 / 45 °C. The light metal housing with an epoxy resin powder coating and a glass that is resistant to temperature changes and impacts meets the requirements for the degree of protection IP66. The modular design allows a fast and economical installation. A durable sealing system for use in extreme ambient conditions offers additional security. The restricted breathing design allows high light outputs and, at the same time, a favourable temperature class T3.

Stainless steel NSSFMV floodlights for particularly harsh environments

The NSSFMV floodlights with high-gloss internal reflectors for high-pressure discharge lamps from 150 W to 400 W fulfil the requirements for hazardous areas in Zone 2 and Zone 22 and ambient temperatures from -25 °C to +55 / 50 °C particularly in harsh environments with a high level of mechanical load, moisture and dust. The stainless steel enclosure with a temperature-change and impact-resistant glass meets the requirements of the degree of protection IP66. The modular design allows a fast and economical installation. A durable sealing system for use in extreme ambient conditions offers additional security. The restricted breathing design allows high light outputs and, at the same time, a favourable temperature class T3.

Wide range of applications

The particularly rugged construction, the high degree of protection and the wide temperature range make these light fittings particularly suitable for offshore applications, in the oil and gas industry and in chemical plants, where explosive atmospheres are to be expected. Further applications include use in explosive gas atmospheres in Zone 2 areas such as oil refineries, ships and drilling platforms, chemical, petrochemical and LNG facilities, waste and wastewater facilities, as well as industrial applications indoors and outdoors. Applications in explosive dust atmospheres in Zone 22 include flour mills, sugar mills, food production, wood processing and other plants with combustible dusts. The NFMV / NSSFMV floodlights feature an adjustable mounting bracket and are suitable for wall and ceiling mounting in medium and large suspension heights. Accessories for pole mounting are also available.

  • FMV5/7/9/13/15L LED floodlights for high power LED modules
  • NFMV and NSSFMV luminaires for high-pressure discharge lamps from 150 W to 400 W
  • Wide temperature range according to type from -45 °C up to +55 °C
  • High degree of protection IP66 for harsh environments

FMV LED

  • FMV 3L CY/UNV1 76 M20
  • FMV 5L CY/UNV1 76 M20
  • FMV 7L CY/UNV1 76 M20
  • FMV 9L CY/UNV1 76 M20
  • FMV 11L CY/UNV1 76 M20
  • FMV 13L CY/UNV1 76 M20
  • FMV 15L CY/UNV1 76 M20
  • FMV 3L CY/UNV1 76 M25
  • FMV 5L CY/UNV1 76 M25
  • FMV 7L CY/UNV1 76 M25
  • FMV 9L CY/UNV1 76 M25
  • FMV 11L CY/UNV1 76 M25
  • FMV 13L CY/UNV1 76 M25
  • FMV 15L CY/UNV1 76 M25

nFMV 25L

  • NFMV 25L CY/UNV1 76 M20

nFMV 50L

  • NFMV 50L CY/UNV1 76 M20

NFMV

  • NFMV HSE 150 W, 230 V 50 Hz
  • NFMV HSE 150 W, 240 V 50 Hz
  • NFMV HSE/HIE 250 W, 230 V 50 Hz
  • NFMV HSE/HIE 250 W, 240 V 50 Hz
  • NFMV HSE/HIE 400 W, 230 V 50 Hz
  • NFMV HSE/HIE 400 W, 240 V 50 Hz

NSSFMV

  • NSSFMV SY 150, 230 V 50 Hz M25
  • NSSFMV SY 250, 230 V 50 Hz M25
  • NSSFMV MY 250, 230 V 50 Hz M25
  • NSSFMV SY 400, 230 V 50 Hz M25
  • NSSFMV MY 400, 230 V 50 Hz M25

Ex lighting – offer

Industrial Lighting
Design

We specialize in industrial lighting, with a particular focus on facilities where there is: dust, corrosive atmosphere, explosion and fire hazards.

AB 05 LED EX ATEX

Ex-Ceiling pendant light fittings and floodlights

Mainly used in explosion-hazard areas, in both land and marine installations, in storage buildings, production halls, and chemical industry facilities.

Ex-linear light fittings

They are made of high-quality plastic with excellent mechanical properties and high resistance to chemicals.

Ex LED lighting

Our light fittings combines the latest LED technology with the protection of a reliable housing solution. As a result, they are the ideal solution for lighting tasks in harsh and hazardous environments.

Ex-escape sign luminaires ATEX

Ex-Signal and escape sign luminaires

The EXIT series of explosion-protected escape sign lumi­naires fulfils the requirements of ATEX Directive 2014/34/EU and EN 60598, Section 2.22 for emergency lighting lumi­naires. The luminaires are suited for marking escape routes and exits in hazardous areas.

Secure your industrial plant

Knowledge base

Do you have any questions?

Donat Czapski Grupa WOLFF zdjecie
DONAT CZAPSKI - I am at your disposal

We will answer questions about: offer, technical specification, delivery, assembly.

or send your inquiry