Ex-d Built-in Components GHG 61
Flameproof encapsulation up to 40 A
If arcing or sparking electrical apparatus are used in hazardous areas, i.e. potentially explosive atmospheres, they must be protected according to EN 60079 pp by special constructional measures. The Eaton’s Crouse-Hinds explosion protected apparatus, such as the modules in Ex-e distributions, derives its high degree of safety through the combination of various types of protection. Thus, flameproof encapsulated components (Ex-d), for instance, are also integrated in enclosures of the type “Increased Safety” (Ex-e).

Safety easy to install
If electrical apparatus is to be used in hazardous areas, i.e. potentially explosive atmospheres, where arcing or sparking can occur, it must be protected according to EN 60079 pp by special constructional measures. Eaton’s Crouse-Hinds Business explosion-protected apparatus, such as the modules in Ex-e distributions, derives its high degree of safety through the combination of various types of protection.
Thus, flameproof encapsulated components (Ex-d), for instance, are also integrated in enclosures of the type “Increased Safety” (Ex-e). As these components are of modular design, they can be combined according to customers’ requirements. Five enclosure sizes provide enough space for whatever modules are required: MCBs, RCDs, RCBOs contactors, motor starters, over-current trips, star-delta time relays or main switches. Protected by a transparent flap, all modules can be conveniently monitored and operated.
The modules are inserted in the distribution by simple snap-on rail mounting. Thus, modules can be replaced or added quickly and reliably. That makes servicing and extension work simpler and faster – and thus more cost efficient.
We’ve also provided for your personal safety: MCBs, RCDs, RCBOs and power circuit breakers can be equipped with a lock in the OFF position. That protects you during your work on the system against inadvertent switching on – better safe than sorry!
- Snap-on
- Individually combinable
- Operation via actuating flap
- Optimum space utilisation with 4 enclosure sizes
- GHG 61 – Ex-d-built-in components
- GHG 612 miniature circuit breaker (MCB)
- GHG 612 residual circuit breaker with Overload (RCBO)
- GHG 612 residual current device (RCD)
- GHG 610 NH 00 main fuse up to 125 A
- GHG 26 main switch / isolator 20 – 180 A
- GHG 618 air-break contactor 20 A
- GHG 618 contactor with thermal release 690 V 4 kW
- GHG 618 installation contactor 20 A up to 32 A
- GHG 618 current impulse switch
- GHG 635 10 manual motor starter
- GHG 618 thermal overcurrent relay
- GHG 618 overvoltage arrester
- GHG 618 multi-function relay
- GHG 600 GRP Ex-e empty enclosures
- GHG 600 Metal Ex-e empty enclosures
- GHG 610 Ex-e actuating flap
- GHG 758 bus bar
- GHG 41 / 23 / 28 Ex d/e control elements
- GHG 41 pushbutton
- GHG 41 key operated pushbutton
- GHG 41 mushroom-head pushbutton
- GHG 41 mini-control switch / potentiometer
- GHG 41 signal lamp / Ex 23/29 control switch
- GHG 41 amp-meter