Ex-Linear light fittings for fluorescent lamps
nLLK 08 18 W – 58 W
(Zone 2, 21, 22)
The linear luminaires series nLLK 08 for fluorescent lamps combines the latest lighting technology with the requirements of a harsh and hazardous environment. This luminaire is available both as a ceiling mounted luminaire (nLLK), as well as a pole mounted light fitting (nLLM) in 3 sizes (18, 36 or 58 W).
Check out HARDO brand OptiLine lighting fixtures
OptiLine lighting fixtures are an excellent alternative to well-known global manufacturers. They are certified for use in zones 2, 21 and 22. The experience of the engineers at HARDO has enabled the identification of typical challenges associated with lighting installations that can increase the overall project costs. As a result of these insights, HARDO engineers have developed an exceptionally versatile lighting fixture suitable for both primary and emergency lighting in explosion hazard zones, all while maintaining reasonable production costs.
Long-term safety
The luminaires of this robust lighting series with plastic enclosure are equipped with a highly-efficient electronic ballast, which has a reliable EOL circuit. Thus, the lamps are checked for proper operation and shut down safely in the event of a malfunction at the end of their service life. With these luminaires, you are always on the safe side.
Simple and cost-effective installation
In conjunction with the generously dimensioned terminal compartment, the standard single-ended through-wiring allows a cost-effective installation. The double-sided locking facility with 10 or 20 latch points allows the protective bowl to be hinged on both sides, meaning that the fitting can be mounted on either side.
Just in case: The emergency lighting version
Safety is always our top priority. That is why we offer the nLLK 08 light fitting series with a built-in V-CG-S module. These luminaires can be connected to a CEAG emergency supply system with individual function monitoring. In the event of an emergency, they provide a reliable illumination of your safety and escape routes. The N variants (Section 1.2.92).are available as emergency light fittings with a self-contained battery unit.
NEC Standards
The tried and tested luminaires of the types nLLK 982217 (2 x 17 W) and nLLK 924232 (2 x 32 W) are available for use according to NEC-standards.
- Cost-effective installation due to single-ended through-wiring
- EVG with EOL monitoring
- Double-sided safety lock
- High degree of protection IP66
- Connection to CEAG emergency light monitoring systems possible (CG-S)
- EVF 120 E (1 x 18 W)
- EVF 140 E (1 x 36 W)
- EVF 165 E (1 x 58 W)
- EVF 240 E (2 x 36 W)
- EVF 265 E (2 x 58 W)
- EVF 120 C (1 x 18/20 W)
- EVF 140 C (1 x 36/40 W)
- EVF 165 C (1 x 58/65 W)
- EVF 240 C (2 x 36/40 W)
- EVF 265 C (2 x 58/65 W)