Ex-Emergency light fittings with a self-cont-ained battery system

Donat Czapski

Donat Czapski – I am at your disposal

+48 695 244 220

info@grupa-wolff.com

Design
Delivery
Installation
Service

We know the requirements of insurers

From ATEX AUDIT to protection implementation

We provide 24/7 service

Ex-Emergency light fittings with a self-cont-ained battery system for fluorescent lamps

eLLK 92018/18 NE / eLLK 92036/36 NE / eLLM 92018/18 NE

(Zone 1, 2, 21, 22)

Emergency lighting luminaires with a self-contained battery system provide a decentralised solution for the mandatory emergency lighting, independent of central systems. In large plants, in particular, these luminaires offer significant cost benefits.

optiline lenses
Looking for a less expensive alternative perhaps?

Check out HARDO brand OptiLine lighting fixtures

OptiLine lighting fixtures are an excellent alternative to well-known global manufacturers. They are certified for use in zones 2, 21 and 22. The experience of the engineers at HARDO has enabled the identification of typical challenges associated with lighting installations that can increase the overall project costs. As a result of these insights, HARDO engineers have developed an exceptionally versatile lighting fixture suitable for both primary and emergency lighting in explosion hazard zones, all while maintaining reasonable production costs.

OptiLine basic lighting fixtures ATEX 12
Ex emergency lighting fixtures with a microinverter
Ex ATEX emergency lighting fixtures powered by a central battery

More safety due to sophis­ticated micro-electronics

Thanks to a new charging and monitoring technology with intelligent micro-electronics, the NE emergency lighting luminaires provide reliable safety and reduced maintenance costs. A function test lasting 5 minutes, that is carried out automatically on a weekly basis, even during mains operation, and a quarterly, partial duty-cycle test provide additional safety and drastically reduce the necessary amount of manual tests. The charging and discharging functions are monitored constantly by the micro-processor and are indicated via a diode display. Only the spent energy is recharged – therefore, overcharging is not possible. The so-called memory effect cannot occur – the service life of the battery is optimized. The need to replace a battery, a fault in the emergency lighting circuit or a faulty battery is indicated by the LED display. Due to a new type of battery connection, the battery can be replaced in the hazardous area. The emergency lighting cycle can be set locally for 1.5 or 3 hours. A remote switch inquiry is standard.

Maintenance possible even in hazardous areas

The battery is installed in a separate, certified housing and Ex-d connectors link the battery unit and the luminaire. After loosening the locking screws, the battery can be taken away, whereby the Ex-d switching contact in the flameproof compartment is cut-off, thus disconnecting the battery circuit. As a result, the battery is cut off completely from the charging circuit of the luminaire and it can therefore, also be replaced in the hazardous area at every time. A detachable strap protects the insert from being dropped inadvertently.

Simple and cost-effective installation

In conjunction with the generously dimensioned terminal compartment, the standard single-ended through-wiring allows a cost-effective installation. The double-sided locking facility with 10 or 20 latch points allows the protective bowl to be hinged on both sides, meaning that the fitting can be mounted on either side.

International certification

Special versions according to the NEC standards are available for use on the American market. CSA certification for the types of luminaires eLLK 92 NE 2217 (2 x 17 W) and eLLK 92 NE 4232 (2 x 32 W) allows their use there.

Other country-specific approvals, such as for Brazil or the new Eurasian Conformity (EAC) for placing them on the market in Russia, Belarus and Kazakhstan, are available.

  • Standard dual channel ballast with EOL monitoring
  • Automatic weekly 5 minute function test
  • Automatic quarterly partial duty cycle test
  • LED display for indication of the charging, operation or fault status
  • Capacity-dependent charging of the battery
  • Easy replacement of battery, even in Ex-area
  • Double-sided central locking facility
  • Safety interlocking system due to an integrated forced isolating switch
  • Safety standard IP66
  • eLLK 92018/18 NE
  • eLLK 92036/36 NE
  • eLLK 92 NIB 2217
  • eLLK 92 NIB 4232

Ex lighting – offer

Industrial Lighting
Design

We specialize in industrial lighting, with a particular focus on facilities where there is: dust, corrosive atmosphere, explosion and fire hazards.

AB 05 LED EX ATEX

Ex-Ceiling pendant light fittings and floodlights

Mainly used in explosion-hazard areas, in both land and marine installations, in storage buildings, production halls, and chemical industry facilities.

Ex-linear light fittings

They are made of high-quality plastic with excellent mechanical properties and high resistance to chemicals.

Ex LED lighting

Our light fittings combines the latest LED technology with the protection of a reliable housing solution. As a result, they are the ideal solution for lighting tasks in harsh and hazardous environments.

Ex-escape sign luminaires ATEX

Ex-Signal and escape sign luminaires

The EXIT series of explosion-protected escape sign lumi­naires fulfils the requirements of ATEX Directive 2014/34/EU and EN 60598, Section 2.22 for emergency lighting lumi­naires. The luminaires are suited for marking escape routes and exits in hazardous areas.

Secure your industrial plant

Do you have any questions?

Donat Czapski Grupa WOLFF zdjecie
DONAT CZAPSKI - I am at your disposal

We will answer questions about: offer, technical specification, delivery, assembly.

or send your inquiry